Hf-scientific MicroTOL Online Turbidimeter Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Hf-scientific MicroTOL Online Turbidimeter. HF scientific MicroTOL Online Turbidimeter User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
OWNER’S MANUAL
MicroTOL Series Turbidimeter
HF scientific
3170 Metro Parkway
Ft. Myers, FL 33916
Phone: 239-337-2116
Fax: 239-332-7643
Toll free: 888-203-7248
Catalog No. 24034 (5/10) E-Mail: [email protected]
Rev. 4.8 Website: www.hfscientific.com
Vue de la page 0
1 2 3 4 5 6 ... 43 44

Résumé du contenu

Page 1 - OWNER’S MANUAL

OWNER’S MANUAL MicroTOL Series Turbidimeter HF scientific 3170 Metro Parkway Ft. Myers, FL 33916

Page 2

MICRO TOL (5/10) 4 Rev. 4.8 1.4 The Touch Pad Figure 2 illustrates the touch pad. The touch pad has four buttons: MODE/EXIT, ↵, t, and u. The MO

Page 3 - DECLARATION OF CONFORMITY

MICRO TOL (5/10) 5 Rev. 4.8 3.0 Installation and Commissioning Prior to use for the first time, the supplied desiccant pouch will need to be insta

Page 4

MICRO TOL (5/10) 6 Rev. 4.8 3.2 Plumbing The recommended plumbing for the instrument is shown in Figure 4. The instrument is designed to require v

Page 5 - Table of Contents

MICRO TOL (5/10) 7 Rev. 4.8 3.2.1 Drain Vent: The Micro TOL has been fitted with a drain vent in the “OUT” bulkhead fitting. This fitting allows

Page 6

MICRO TOL (5/10) 8 Rev. 4.8 Figure 5: Electrical Connections for the Instrument 3.3.1 Power: The instrument is equipped with a 100-240

Page 7 - Specifications

MICRO TOL (5/10) 9 Rev. 4.8 4.0 Operation This process turbidimeter allows for the measurement of the turbidity of process water on-line. The turb

Page 8 - 1.0 Overview

MICRO TOL (5/10) 10 Rev. 4.8 The security code (333) must be entered to gain access to CAL or CONFIG menus. Notice that the first number in the c

Page 9

MICRO TOL (5/10) 11 Rev. 4.8 5.0 Instrument Calibration The instrument was calibrated and tested prior to leaving the factory. Therefore, it is po

Page 10 - 2.0 Safety

MICRO TOL (5/10) 12 Rev. 4.8 5.2 Calibration Procedures 1. Select the calibration function of the instrument by pressing the MODE/EXIT button once

Page 11

MICRO TOL (5/10) 13 Rev. 4.8 12. Insert the requested 0.02 NTU standard. Index the standard to the lowest value on the upper display. 13.

Page 13

MICRO TOL (5/10) 14 Rev. 4.8 6.0 Instrument Offset In certain instances, it may be desirable to use an offset factor to calibrate the instrument ra

Page 14

MICRO TOL (5/10) 15 Rev. 4.8 7. If the option was turned On, the upper row will display the offset required. This will add or subtract the value

Page 15 - 4.0 Operation

MICRO TOL (5/10) 16 Rev. 4.8 7.0 Instrument Configuration (CONFIG mode) The instrument has been designed to provide the ability to customize the

Page 16 - button

MICRO TOL (5/10) 17 Rev. 4.8 Note: The 4MA can be set higher than the 20 MA level to invert the output current if required. This may be required t

Page 17 - 5.0 Instrument Calibration

MICRO TOL (5/10) 18 Rev. 4.8 7.4 Configuring the RS–485 Port If the instrument is equipped with this option, and the I/O selection is changed to 4

Page 18 - ↵, requesting the 0.02 NTU

MICRO TOL (5/10) 19 Rev. 4.8 These three items are described below: Alarm Function: The alarms can either be turned OFF or programmed to operate i

Page 19

MICRO TOL (5/10) 20 Rev. 4.8 Alarm 1 Delay Times: Delay On: The following display will appear to allow to select the number of seconds currently

Page 20 - buttons

MICRO TOL (5/10) 21 Rev. 4.8 7.7 Enabling the Security Access The instrument is equipped with a security access. If this option is turned on, the

Page 21

MICRO TOL (5/10) 22 Rev. 4.8 7.10 Displayed Resolution The instrument is equipped with the ability to display several levels of resolution. The in

Page 22 - ↵ button

MICRO TOL (5/10) 23 Rev. 4.8 The most common unit is NTU (Nephelometric Turbidity Units) however the instrument can display in FNU (Formazin Nephel

Page 23

DECLARATION OF CONFORMITY Application of Council Directive Standards to Which Conformity is Declared: Product Safety - Tested and passed ETL (

Page 24

MICRO TOL (5/10) 24 Rev. 4.8 7.15 Desiccant Alarm When the humidity detector in the Micro TOL indicates that the internal environ

Page 25

MICRO TOL (5/10) 25 Rev. 4.8 7.16 4mA Adjustment If the 4-20 mA setting is turned ON (7.2 Setting the 4-20 mA Output), the following two menus will

Page 26

MICRO TOL (5/10) 26 Rev. 4.8 8.0 Additional Features and Options 8.1 Backlit LCD The backlit LCD allows for easier readability of the LCD dis

Page 27

MICRO TOL (5/10) 27 Rev. 4.8 FLOW THROUGHCUVETTEULTRASONICTRANSDUCERSENSOR(TOP VIEW)ULTRASONICSPRINGCONNECTIONS Figure 6: Operational part

Page 28

MICRO TOL (5/10) 28 Rev. 4.8 • The same attention character “:” in ASCII or 3A Hex • The address of the Micro TOL • The Reading • The Unit (NTU

Page 29

MICRO TOL (5/10) 29 Rev. 4.8 9.0 Troubleshooting & Maintenance 9.1 Micro TOL Fault Detection The Micro TOL performs continuous diagnostic mo

Page 30

MICRO TOL (5/10) 30 Rev. 4.8 9.3 Diagnostic Chart Symptom Cause Cure Lower display shows MA 4-20 mA loop open Check wiring. See sections 3.3.4

Page 31

MICRO TOL (5/10) 31 Rev. 4.8 10.0 Routine Maintenance 10.1 Cleaning the Flow Through Cuvette Measurement cuvettes used for both grab sample and the

Page 32

MICRO TOL (5/10) 32 Rev. 4.8 11.0 Accessories and Replacement Parts List The items shown below are recommended accessories and replacement part

Page 33 - CONNECTIONS

MICRO TOL (5/10) 33 Rev. 4.8 12.0 Warranty HF scientific inc., as vendor, warrants to the original purchaser of this instrument that it will be fre

Page 40

MICRO TOL (5/10) Rev. 4.8 Table of Contents Section Page Specifications ...

Page 41

MICRO TOL (5/10) Rev. 4.8 Table of Contents (continued) Section Page 7.6 Offs

Page 42

MICRO TOL (5/10) 1 Rev. 4.8 Specifications Measurement Range 0 – 1000.0 NTU 0 – 100 NTU (Model 20055 & 20056) Accuracy ±2% of reading or ±0.0

Page 43

MICRO TOL (5/10) 2 Rev. 4.8 1.0 Overview The MICRO TOL process turbidimeter allows for the measurement of the turbidity of process water on-line

Page 44

MICRO TOL (5/10) 3 Rev. 4.8 1.2 Unpacking and Inspection of the Instrument and Accessories The table below indicates the items in the turbidimeter

Commentaires sur ces manuels

Pas de commentaire